Medical Device Regulation (MDR) and Medical Devices

Amazon & D2C glossary · Harpy Media

The EU Medical Device Regulation governs medical devices by risk class, requiring conformity assessment, CE marking, clinical evidence and post-market surveillance.

Scope and classification

MDR (2017/745) covers devices intended for diagnosis, prevention, monitoring, treatment, or alleviation of disease or injury. Devices are classified into classes I, IIa, IIb and III by risk, with class I having sub-classes including sterile and measuring variants. Classification determines the conformity route: class I can often self-certify, while IIa and above require a notified body.

Many products sellers think of as consumer wellness goods — massage devices, thermometers, bandages, toothbrushes with therapeutic claims — fall within scope.

Requirements

  • Conformity assessment — technical documentation and, above class I, notified-body involvement.
  • CE marking and a declaration of conformity citing MDR.
  • Clinical evaluation — evidence supporting safety and performance claims.
  • UDI — unique device identification and registration in EUDAMED.
  • Post-market surveillance and vigilance reporting for incidents.
  • Authorised representative — required where the manufacturer is outside the EU.
  • Labelling and IFU — language and content requirements per member state.

Where marketplace sellers get caught

Claiming a wellness benefit that reclassifies a general consumer product as a medical device without the corresponding conformity work; importing devices with a supplier's CE mark but no access to the technical file; and omitting UDI and vigilance obligations entirely. In a category where an adverse event triggers reporting duties, the gap between "it's just a massager" and "this is a class IIa device" can be the whole business.

⚠️ Watch out. Marketing claims determine classification — describing a product as treating a condition can turn a consumer item into a regulated device, and the compliance burden follows the claim.

Practical approach

  1. Classify before listing — determine intended purpose and risk class in writing.
  2. Get the technical file — as a seller you need access, not just a certificate.
  3. Check the claim language against what the conformity assessment supports.
  4. Confirm UDI and registration status for the exact device.
  5. Set up vigilance — a route to report incidents rather than discovering one in a review.
  6. Review annually — the regulation has been tightening its interpretation since application.

Claims review before listing

Write down every claim the listing makes, then ask for each whether the conformity assessment and clinical evidence support it. Claims about diagnosing, treating, curing, or preventing disease are the ones that define classification and liability. If a marketing team wants a stronger claim than the evidence supports, the answer is to change the claim, not the listing wording to make it subtly imply the same thing.

Post-market obligations

Compliance does not end at launch. MDR requires post-market surveillance, periodic safety reporting, and vigilance notification for serious incidents. As the entity placing devices on the market, you need a route for customers to report problems and a process that evaluates and escalates them. A serious incident discovered in a review and reported weeks late is a regulatory matter, not a customer-service one.

Where the line sits for accessories

Accessories can be classified differently from the device they support — a case or strap is generally not a medical device, while a replacement sensor or a sterile component may be. The distinction matters because accessories can be cheaper to launch. Get the classification documented per item rather than generalising from the parent product.

A launch readiness list

Intended purpose written down; risk class documented; conformity route identified; technical file accessible; CE marking and DoC in place; UDI assigned and registered; EU representative appointed if needed; IFU translated; vigilance process defined; category approval requested from the marketplace. Ten items, and a device missing any of the last three can still be removed from sale after launch.

Medical Device Regulation FAQ

What are the MDR risk classes?

I, IIa, IIb and III, with increasing assessment requirements.

Do I need a notified body?

For most class IIa and above devices, yes.

Are spare parts covered?

Devices and accessories fall within scope of the regulation.

How long does conformity take?

Months to years depending on class and clinical evidence.

Can I list without CE marking?

Not for devices in scope within the EU — listing would be non-compliant.