Low Voltage Directive (LVD)
The Low Voltage Directive is the EU rule covering electrical equipment between 50 and 1,000 volts AC — requiring CE marking, safety documentation, and conformity assessment.
Scope
The LVD (2014/35/EU) applies to electrical equipment operating in a voltage range of 50–1,000 V AC or 75–1,500 V DC. That covers a very large share of consumer electricals: chargers, adapters, small appliances, lighting, and power tools. It sets essential safety requirements and sits alongside electromagnetic compatibility and, where applicable, radio equipment rules.
Equipment below the voltage threshold is not covered by the LVD but is still covered by the General Product Safety Regulation and other applicable law.
What compliance requires
- Safety objectives met — typically demonstrated against harmonised standards.
- Technical documentation — design, components, test evidence, risk assessment.
- Conformity assessment — usually internal production control with the technical file.
- CE marking — affixed to the product or, where impractical, to packaging and documents.
- EU declaration of conformity — identifying the manufacturer or authorised representative and the directives applied.
- Traceability — manufacturer/importer identification on the product.
- Instructions and safety information in the language(s) required by the member state.
Where marketplace sellers get it wrong
Buying from a non-EU supplier and assuming the supplier's CE mark transfers responsibility; listing a product whose charger was never tested to the applicable standard; holding no technical file and no DoC; and omitting the EU responsible-person details. When Amazon requests documentation for an electrical product, the absence of a technical file is not a paperwork gap — it means the product cannot be shown compliant.
Documentation pack to hold
- EU declaration of conformity, signed and current.
- Test reports against the applicable harmonised standards.
- Technical file with component list and safety assessment.
- Product and packaging artwork showing CE marking and importer details.
- Instruction manuals in required languages.
- Battery and WEEE/EPR registrations where applicable.
Practical preparation for an audit
Keep the pack per SKU, current, and in one place with the SKU as the filename prefix. When a compliance request arrives — usually with a short deadline — responding in hours rather than weeks is the difference between a listing remaining live and a suspension followed by reinstatement weeks later. For electrical goods, the LVD pack is the most frequently requested document set after safety labelling.
Testing costs versus the risk
LVD testing for a simple mains-powered product typically runs into the low thousands of euros, depending on complexity. A single safety incident, recall, or marketplace suspension costs substantially more — and the cost of being unable to produce a technical file when requested is the entire revenue line for that product while it sits suspended. Budget testing into the product development plan, not the listing-launch scramble.
LVD versus EMC and RED
Electrical products often need more than the LVD: electromagnetic compatibility rules apply to almost all electronics, and radio equipment has its own directive with additional testing. A Declaration of Conformity that cites only the LVD for a Bluetooth device is incomplete, and reviewers who know the categories spot it immediately. Map every product against all applicable directives before listing.
Documentation maintenance
When a component changes, the technical file must be updated and the conformity assessment re-checked — a new power supply can invalidate the testing behind the CE mark. Treat every BOM change as a compliance event, route it through the same review that approves the cost change, and the file stays current instead of being reconstructed in a panic after a support request.
LVD FAQ
Do I need a notified body?
Usually not — internal production control with a technical file is the standard route for LVD.
Does the LVD cover battery-powered products?
Only within its voltage range; mains chargers for such products usually are covered.
Is UKCA still relevant?
Yes for the UK market — parallel but distinct marking requirements.
Who is the EU responsible person?
An EU-established entity accountable for compliance and documentation.
How long do I keep documents?
Typically ten years from the last unit placed on the market.
Want these numbers watched for you, every week?
Book Free Consultation